Hardware Diagnostics
Items of Hardware Diagnostics

96

At the start of the test, the message to change the Hardware
Diagnostics test diskette with the test diskette appears. Change
disks at this point.

[01. Sequential address read]

This subtest reads data from all tracks continuously on a
diskette.

[02. Random address data W/R/C]

This subtest writes random data to random addresses on all
tracks on the diskette. The data is then read and compared to
the original data.

NOTE: This test requires that the test diskette be formatted
and write-enabled.
Make sure that there is no important data on the test diskette,
as the contents may be modified during the test.

FLOPPY DISK TEST (FDD) Error log

*Address during the test (ADDRESS: 0tthss)

0 tt h ss

tt

: Track address

h

: Head address

ss

: Sector address

Status

Error name

Meaning

01

BAD COMMAND ERROR

Bad command error has occurred

02

ADDRESS MARK NOT FOUND

The address mark has not been found

03

WRITE PROTECED

Floppy disk is write-protected

04

RECORD NOT FOUND

The record has not been found

06

MEDIA CHANGE LINE ERROR

The media change line is bad

08

DMA OVERRUN ERROR

DMA OVERRUN occurred

09

DMA BOUNDARY ERROR

DMA BOUDARY occurred

10

CRC ERROR

CRC check error

20

FDC ERROR

FDC error

40

SEEK ERROR

Floppy disk seek error