Toshiba Magnia 3310 User Manual
Page 108
Hardware Diagnostics
Items of Hardware Diagnostics
104
The test detects the SAF-TE controller first and shows the
connecting destination of the detected SAF-TE controller (host
number, SCSI ID, and channel number) with model name.
After detecting the SAF-TE controller, the following message
appears:
When the message above appears, check that all LEDs of the
hard disk drives light in orange. Then press <Enter> key.
When the message above appears, check that all LEDs of the
hard disk drives are flashing orange. Then press <Enter> key.
When the message above appears, check that all LEDs of the
hard disk drives light in orange. Then press <Enter> key.
When the message above appears, check that all LEDs of the
hard disk drives are flashing orange. Then press <Enter> key.
When the message above appears, check that all LEDs of the
hard disk drives turn off. Then press <Enter> key.
SAF-TE TEST (SAF) Error log
--HT-ID----CH--VENDOR-PRODUCT-------FAN-PS--SLOT XX XX
XX XXXXX XXXX XX XX XX
SAF-TE LED Steady ON (Faulty Flag) Hit any key
SAF-TE LED Blinking (Rebuilding Flag) Hit any key
SAF-TE LED Steady ON (Rebuild Interrupted) Hit any key
SAF-TE LED Blinking (Rebuilding Flag)
Hit any key
SAF-TE LED Reset (No Error Flag)
Hit any key
Status
Error name
Meaning
01
SAF-TE TEST ERROR
SAF-TE controller has not been detected.