Hardware Diagnostics
Items of Hardware Diagnostics

98

SCSI ID NUMBER

This option sets the SCSI ID to test. You can specify just one ID to
test except ID:7.

CHANNEL NUMBER

If the server has multiple SCSI channels, this option sets the
channel number to test.

[01. Sequential address read]

This subtest is a sequential reading of all the blocks on the
HDD, starting at block 0.

[02. Connection]

This subtest reads the logical sector at the end of the HDD, and
then recognizes if the drive is connected or not.

NOTE: The [01. Sequential address read] tests all areas of
the hard disk drive. If the capacities of installed hard disk
drives are large enough, the test may take a few hours.
If you do not know where the hard disk drives are connected
(host ID, SCSI ID and channel number of the SCSI
controller), you can find them from [01. INQUIRY] of [09.
SCSI TEST].

SCSI HDD TEST (HDD)

Status

Error name

Meaning

01

CHECK CONDITION OR BAD
COMAND

Bad command error

03

DRIVE SELECTION FAILED

ID selection error

04

TARGET DRIVE BUSY

The target drive is busy

05

SCSI BUS TIME OUT

Time out error of SCSI bus

09

DMA BOUNDARY ERROR

DMA BOUNDARY occurred

0D

COMMAND TERMINATED

A command terminated

0E

QUEUE FULL

Command queue is full

80

NO SENSE

The sense data is invalid

81

RECOVERED ERROR

The execution of the command has correctly
finished because of recovery treatment