DS-RPC OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
__________________________________________________________________________________________

23

SELECTING A DEVICE There are two methods of selecting a device,

menu driven selection and ASCII character
string method.

Menu Driven From the main menu, select the number that
Selection

corresponds to the device you wish to
access, followed by <cr>. To return to the
main menu, send the attention character five
times (;;;;;).

ASCII Character Another method of selecting devices and
String operating the DS-RPC is the ASCII

character string method. To select a device
located on a peripheral module port, send
the port select code (default is $BT), the
module number, a comma, and then the port
number, followed by <cr> (there are no
spaces in the string). For example, to select
port 4 located on module 2, type BT2,4<cr>.
To select port 1 on module 9 (DS9 model),
type $BT9,1<cr>. To disconnect, type
$BT<cr>, then the attention character.

To configure a module, type $BT and the
module number followed by <cr>, then
$CONFIG followed by <cr>. This will allow
access to the configuration menu for that
module. Once configuration is complete,
type X for “Exit” followed by <cr>. To
access the main menu, type the attention
character five times.

NOTE: You must exit main menu to send ASCII character string
commands.

NOTE: While operating using the ASCII Character String method,
consider placing the DS-RPC in binary mode.