DS-RPC OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
__________________________________________________________________________________________

45

From the configuration menu, select #9,
“DCD Logon/Logoff,” followed by <cr>.
The DS-series module displays the current
DCD Logon/Logoff status and asks if you
want to change: DCD logon/logoff factory
default is enabled:

DCD Logon/Logoff mode is................. Enabled
Enable ? (Y/N, CR for no change) :

Type “Y“ for yes followed by <cr>. Type
“N” for no followed by <cr>. Type <cr> for
no change.

LOCAL MODEM SETUP The DS71-MD2 has an internal 14.4K bps
DS71-MD2 ONLY) modem. Programmable modem

characteristics include number of rings to
answer, modem to modem Xon/Xoff
handshaking, amount of inactivity before the
modem automatically disconnects
(connectivity time-out), and the escape
character used to tell the modem the
information you are sending is a command
and not data (command mode).

From the configuration menu, select #9,
“Local Modem Setup,” followed by <cr>.
The following Local Modem Setup menu
appears:

Local Modem Setup:
Rings to Answer......…..............................1
Modem to Modem Xon/Xoff....................2
Connectivity Time-Out.............................3
Escape Character
........…..........................4
Exit..................................….......................X

Enter Request: