Bay Technical Associates DS4-RPC User Manual

Page 62

Advertising
background image

DS-RPC OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
__________________________________________________________________________________________

55

From the configuration menu, select #1,
“Module IP Address,” followed by <cr>.
The DS73TP responds:

Enter Module IP address in dotted decimal form:

Enter the Module IP Address (Example:
200.4.3.50), followed by <cr>. The
DS73TP resumes the configuration
menu.Default Module IP Address is
0.0.0.0.

If you fail to enter the Module IP Address in
dotted decimal form, the DS73TP responds
again:

Enter Module IP address in dotted decimal form:

The DS73TP responds indefinitely with the
same request until the Module IP Address in
entered in the correct form.

IMPORTANT: The Module IP Address and the Dial-Up Address
must be different in order for the DS73 series module to function
correctly.

NOTE: There should be no active connections while configuring
the DS7 modue, and the unit should be reset upon completion of
configuration.

Dial-UP

The Dial-up IP Address consist of four

IP Address bytes, each byte ranging from 0 to 255.

This parameter must be programmed
before the DS-Series can be accessed on
the network.

From the configuration menu, select #2,
“Dial-UP IP Address,” followed by <cr>.
The DS73TP responds: