Connection wiring diagram, 607c -- -- a, Dip switch settings – Bryant 607C-A User Manual

Page 42: Legend

Advertising
background image

42

FIELD

SUPPLY

C F

SCHEMATIC
208/230-3-60

1

1

EQUIP_GND

COMP

T1

T2

T3

PRIMARY

208/230V

TRAN

SECONDARY

24 V

24V

C

230

COM

OFM

CAP1

YEL

BRN

C

11

21

13

23

BLK

YEL

BLU

COMPRESSOR PLUG

YEL

BLK

BLK

BLK

CCH

GRN

HIGH

IFB

DEHUM

STD

BLK

YEL

BRN

BLK

BLK

DIP SWITCH
SETTINGS

30

MINUTES

60

MINUTES

ON

DEFAULT

90

MINUTES

OR

OFF

SHIFT

(DEFAULT)

QUIET

OR

OR

FIELD SELECTABLE OPTIONS FOR TIME PERIOD
BETWEEN DEFROST CYCLES (MINUTES)

1) MOMENTARILY SHORT PINS AND RELEASE TO BYPASS

COMPRESSOR OFF DELAY.

2) SHORT FOR 5+ SEC. AND RELEASE FOR FORCED

DEFROST.

3) PERMANENT SHORT WILL BE IGNORED.

DEFROST WILL TERMINATE IN 30 SEC. IF DFT OPEN.
DEFROST WILL TERMINATE NORMALLY IF DFT IS
CLOSED.

THE COMPRESSOR WILL SHUT OFF FOR 30 SEC. ON
DEFROST INITIATION AND TERMINATION IN THE
”QUIET SHIFT” ON POSITION

SPEED

UP

JUMPERED TEST PINS (USE METAL OBJECT)
FIELD SPEED-UP CYCLE

11

1

1

1

33

3

3

3

22

2

2

2

120

MINUTES

0

G

ENERGIZED

T

G

DE-ENERGIZED

0

W

45

BR

T

W

T+45

BR

ENERGIZED DE-ENERGIZED

T+90

HEATING FAN LOGIC

COOLING FAN LOGIC

ACCESSORY ELECTRIC HEAT

HR1 (5 KW)

HR1 & 2 (10 KW)

HR1-3 (15 KW)

HR1-4 (20 KW)

HR3

HR2

HR4

HR1

BRN
BRN

BRN

BRN

BRN

1

1

1

1

1

WHT

VIO

PNK

GRY

BRN

WHT

VIO

PNK

GRY

BRN

7

6

11

10

8

2

3

4

1

5

9

12

7

6

11

10

8

2

3

4

1

5

9

12

NOTES:
1. IF ANY OF THE ORIGINAL WIRES FURNISHED ARE REPLACED,

THEY MUST BE REPLACED WITH THE SAME WIRE OR ITS EQUIVALENT.

2. SEE PRICE PAGES FOR THERMOSTATS.
3. USE 75 DEG. COPPER CONDUCTORS FOR FIELD INSTALLATION.
4. SEE INSTALLATION INSTRUCTIONS

FOR PROPER HEATING AND COOLING CONNECTIONS
FOR YOUR UNIT. INDOOR FAN MOTOR PLUGS
- ”DO NOT DISCONNECT UNDER LOAD”

5. THIS FUSE IS MANUFACTURED BY LITTELFUSE, P/N 257003.
6. REMOVE YELLOW SPLICE WHEN ECONOMIZER AND ECONOMIZER

RELAYS ARE USED AND CONNECT TO RELAY R1 AS SHOWN.

7. WHEN ECONOMIZER AND ECONOMIZER RELAYS ARE USED,

CONNECT THE YELLOW AND BLACK WIRES TO RELAY ”R” AS
SHOWN. RELAY KIT REQURED WITH ECONOMIZER AND HEAT
PUMP/DUAL FUEL UNITS.

8. WHEN ECONOMIZER AND ECONOMIZER RELAYS ARE USED, INSTALL

WIRES AS SHOWN ONTO THE COILS OF RELAY R AND RELAY R1.

9.DEHUM FEATURE CANNOT BE USED WHEN ECONOMIZER IS INSTALLED.

UNIT FACTORY-SHIPPED
IN STD MODE.

COMP

COMPRESSOR MOTOR

EQUIP

EQUIPMENT

GND

GROUND

IFM

INDOOR FAN MOTOR

OFM

OUTDOOR FAN MOTOR

TRAN

TRANSFORMER

IFB

INDOOR FAN BOARD

LPS

LOW PRESSURE SWITCH

HPS

HIGH PRESSURE SWITCH

T-STAT

THERMOSTAT

DB

DEFROST BOARD

DFT

DEFROST TEMPERATURE
SWITCH

DR

DEFROST RELAY

HR

HEATER RELAY

RVS

REVERSING VALVE

OFR

OUTDOOR FAN RELAY

LEGEND

FIELD SPLICE
TERMINAL (MARKED)
TERMINAL (UNMARKED)
SPLICE (IF REQ’D)
SPLICE (MARKED)
FACTORY WIRING
FIELD CONTROL WIRING
FIELD POWER WIRING
ACCESSORY OR OPTIONAL
WIRING

C

CONTACTOR

CAP 1

CAPACITOR, COMP

CCH

CRANK CASE HEATER

AT

AUTO TRANSFORMER
460V - 230V

FU

FUSE

R

ECON RELAY

R1

ECON RELAY

DH

DEHUMIDIFICATION MODE

DEHUM

DEHUMIDIFICATION MODE

ECON

ECONOMIZER

STD

STANDARD MODE

BLK

BLK

YEL

DANGER: ELECTRICAL SHOCK HAZARD DISCONNECT POWER BEFORE SERVICING

CONNECTION WIRING DIAGRAM

YEL

IFM

G

N

L

C

1 2435

YEL

BRN

RED

BRN

G/Y

IF USED

BLK

BLK

DR

OF1

OF2

BLK

BLK

RED

BLU

PNK ORN

G/Y

BLU

L1

L3

L2

COLOR CODE

BLK

BLACK

BLU

BLUE

BRN

BROWN

GRY

GRAY

GRN

GREEN

ORN

ORANGE

PNK

PINK

RED

RED

VIO

VIOLET

WHT

WHITE

YEL

YELLOW

C

C1

C2

BLU

YEL

RED

GRN

VIO

Y1

R

G

V

BRN

C

O

PNK

RVS

DFT

60

30

120

90

UP

SPEED

P1

P3

P2

CTD

DEFROST BOARD (DB)

DR

OF2

OF1

0

W2

R

Y

DFT

T2

T1

O

R

Y

C

C

C

BLK

BRN

BRN

PNK

BRN

WHT

ORN

RED

P4

P2

P1

R

C

COM

3A

FUSE

Y

1
2

4

3

5

1
2
3

4

Y

R

W2

C

W2
W3
W3

C

W2

COM

24VAC

COM

5

4

3

2

1

6
7

W3

W2

G

Y2/DH

Y1/Y

R
C

WHT

W

BRN

WHT

VIO

PNK

GRY

BRN

WHT

ORN

RED

BRN

SEE NOTE 5

SAT

BLU

BLU

ECON

BLK

R

1

2

3

R1

1

2

3

YEL

YEL

YEL

BLK

GRY

Y2

T-STAT

YEL

RED

BRN

R1

C1

C2

R

C1

C2

SEE

NOTE 4

FOR WIRING WITH
ELECTRIC HEATERS
SEE SCHEMATIC ON
HEATER ACCESSORY.

BLU

DH

LOW

SEE NOTE 9

SEE NOTE 8

SEE NOTE 7

SEE NOTE 6

BLU

BLK

BLU
BLU

HPS

LPS

BLK

BLU

TRAN

CONTROL BOX AREA

24V SPLICE
BOX

24V POWER

ENTRY

INDOOR FAN
SECTION

23

23

21

C

11

COMPRESSOR
SECTION

UNIT COMPONENT ARRANGEMENT

OUTDOOR FAN
SECTION

OFM

LPS

R

C

S

CCH

COMP

DB

HPS

CAP

HC

F

SINGLE PT.
CONNECTION
FOR
ELEC. HEAT

IFB

DISCONNECT
PER NEC

BLK

BRN

RED

YEL

GRY

ECONOMIZER PLUG

P

P

SEE

50SD500625

ECONOMIZER

LABEL

DIAGRAM

BLK

A10200

Fig. 46 -- Connection Wiring Diagram 230--3

607C

--

--

A