Service mode, Ervice – Bacharach AGM300 User Manual

Page 69

Advertising
background image

Instruction 3015-4275

61

Service Mode

When activated, the Service Mode will disable a specific AGM300 unit for a specified length of time. The default
is 60 minutes. This time interval can be changed per Section Service Timeout on Page 40.

IMPORTANT: Note that while in the Service Mode no measurements are made, nor are any alarms activated.

From the System Screen (Page 31), select the key adjacent to the AGM unit you wish to place into its Service
Mode. From AGM Setup Screen #1 (Page 37) press the SERVICE MODE ENTRY key twice within
3 seconds
.

Note that the System Screen will show what monitors are in the Service Mode.

To exit the Service Mode, again press the SERVICE MODE ENTRY key twice within 3 seconds.

AGM Setup Screen #1















System Screen (Service Mode)















Press this key
twice within
3 seconds to
place the
selected AGM
unit into its
Service Mode

Monitor in

Service

Mode

Advertising
This manual is related to the following products: