SECTION 2.4

DIAGNOSTIC TESTS

AC GENERATORS

TEST 4- FIXED EXCITATION TEST

/ROTOR AMP DRAW TEST

DISCUSSION:
Supplying a fixed DC current to the rotor will induce a
magnetic field in the rotor. With the generator
running, this should create a proportional voltage
output from the stator windings.

PROCEDURE:

1. Disconnect Wire 4 from the voltage regulator, 3rd

terminal from the top. See Figure 3.

2. Connect a jumper wire to the disconnected Wire 4 and

to the 12 volt fused battery supply Wire 15. (located at
15A fuse).

Figure 3. Voltage Regulator

3. Set VOM to AC volts.

4. Disconnect Wire 2 from the excitation circuit breaker

(CB2) and connect one meter test lead to that wire.
Disconnect Wire 6 from the voltage regulator and
connect the other meter test lead to that wire. (5th
terminal from top, double check wire number).

5. Set the AUTO-OFF-MANUAL switch to MANUAL. Once

the engine starts, record the AC voltage.

6. Set the AUTO-OFF-MANUAL switch to OFF. Reconnect

Wire 2 and Wire 6.

7. Disconnect Wire 11 from the voltage regulator and

connect one meter test lead to that wire. Disconnect
Wire 22 from the voltage regulator and connect the
other meter test lead to that wire (both wires are located
at the top two terminals of the voltage regulator, see
Figure 3).

PART 2

TEST 4 RESUL

TS - FIXED EXCIT

A

TION TEST/R

O

T

OR AMP DRA

W TEST

Results:

Size

ABCD

E

F

G

H

Voltage Results

ALL

Above 60 VAC

Above 60 VAC

Below 60 VAC

Zero or

Below 60 VAC

Below 60 VAC

Above 60 VAC

Below 60 VAC

Wire 2 & 6

Residual Volts

Voltage Results

ALL

Above 60 VAC

Below 60 VAC

Above 60 VAC

Zero or

Below 60 VAC

Below 60 VAC

Above 60 VAC

Below 60 VAC

Wire 11 & 22

Residual Volts

Static Rotor

6 & 7 kW

0.91-1.06A

0.91-1.06A

0.91-1.06A

Zero

Above 1.5A

0.91-1.06A

Zero

0.91-1.06A

Amp Draw

12 & 12 kW

0.80A

0.80A

0.80A

Current

Above 1.3A

0.80A

Current

0.80A

13 & 15 kW

0.64A

0.64A

0.64A

Draw

Above 1.1A

0.64A

Draw

0.64A

Running Rotor

6 & 7 kW

0.91-1.06A

0.91-1.06A

0.91-1.06A

Zero

Above 1.5A

0.91-1.06A

Zero

Above 1.5A

Amp Draw

12 & 12 kW

0.80A

0.80A

0.80A

Current

Above 1.3A

0.80A

Current

Above 1.3A

13 & 15 kW

0.64A

0.64A

0.64A

Draw

Above 1.1A

0.64A

Draw

Above 1.1A

MATCH

RESULTS

WITH

LETTER

AND REFER TO FLOW CHART IN SECTION 2.3 “Problem 1”