Mcs-d 200 control unit, 5 rack mounting, 6 how to supply the system – Beyerdynamic MCS-D 200 User Manual

Page 11: 4 how to connect a pc or media control system

Advertising
background image

MCS-D 200 Control Unit

E

11

3.2.5

Rack mounting

• When mounting the MCS-D 200 control unit into a 19"-rack housing leave 1 U for a ventilation panel above and

under the control unit.

• Make sure that the mains switch, mains plug and all connection on the rear of the device are easily accessible.

3.2.6

How to supply the system

• All microphone stations, D/A interfaces and adapters are powered via the system. They do not have their own power supply.
• The number of the required power supply units depends on the number of microphone stations and the system set-up

including different cable lengths and operating mode.

• The following list shows how many devices such as microphone stations, interfaces and adapters can be powered by the

system.

MCS-D 200 control unit with 1 power pack (= 2 A)

for approx. 15 microphone stations

MCS-D 200 control unit with 2 power packs (= 4 A)

for approx. 30 microphone stations

When the system is extended with additional power supply units:
Power supply unit with 1 power pack (= 2 A)

for approx. 15 microphone stations

Power supply unit with 2 power packs (= 4 A)

for approx. 30 microphone stations

Power supply unit with 3 power packs (= 6 A)

for approx. 45 microphone stations

Note:
In this rule of thumb, an adapter (CA 4212/13/14 or CA 4222/23/24) approximately counts as half a microphone station.

Example of a system set-up:

1 MCS-D 200 control unit with 2 power packs . . . . . . . . . . . . 10 MCS-D 202 interpreter stations

+ 1 D/A interface
+ 2 adapters

+

1 Power supply unit with 2 power packs . . . . . . . . . . . . . . . . . for 30 microphone stations

+

1 Power supply unit with 3 power packs . . . . . . . . . . . . . . . . . for 45 microphone stations

3.2.4

How to connect a PC or media control system

• If you would like to connect a PC or media control system to the MCS-D 200 control unit, use the RS 232 connection or .
• In order to connect a PC use a standard RS 232 cable, straight - no null modem cable. If you connect other devices, please

observe the pin assignment.

• The system is configured via the MCS-D 200 control unit, please refer also to chapter 3.3 “How to operate the menu of the