SECTION 5 - JLG CONTROL SYSTEM

3121122

– JLG Lift –

5-9

4-4

440

BATTERY SUPPLY

441

BATTERY VOLTAGE TOO LOW - SYSTEM SHUTDOWN
Recharge batteries or check for damaged batteries.

442

BATTERY VOLTAGE TOO HIGH - SYSTEM SHUTDOWN
Disconnect battery charger. Check that the correct voltage batteries are being used.

N/A

BATTERY CHARGE TOO LOW - SYSTEM SHUTDOWN

6-6

660

COMMUNICATION

661

CANBUS FAILURE: POWER MODULE
Lost communication to power module. Check wiring at ground control and power module. Recycle power to clear fault.

7-7

770

ELECTRIC MOTOR

773

CAPACITOR BANK FAULT - CHECK POWER CIRCUITS
Check power wiring. If no error in power wiring, replace power controller.

775

OPEN CIRCUIT FIELD (or TRACTION) WIRING
Open circuit between F1 and F2 terminals on power module and the drive motors. Check wiring.

8-1

810

TILT SENSOR

812

NO DATA FROM TILT SENSOR - NOT CONNECTED OR FAULTY
No signal from the tilt switch. Check wiring and plug connections at the level sensor and at the ground control box.

9-9

990

HARDWARE

995

POWER MODULE FAILURE - PERSONALITY RANGE ERROR
Toggle MODEL then re-configure Machine Setup and Personalities. If this does not resolve issue, replace power controller.

996

POWER MODULE FAILURE - INTERNAL ERROR
Toggle MODEL then re-configure Machine Setup and Personalities. If this does not resolve issue, replace power controller.

997

POWER MODULE FAILURE - CHECK POWER CIRCUITS OR MOSFET SHORT CIRCUIT
Check power wiring. If no error in power wiring module, replace power controller.

9980

POWER MODULE FAILURE - PERSONALITY CRC ERROR
Toggle MODEL then re-configure Machine Setup and Personalities. If this does not resolve issue, replace power controller.

N/A

POWER MODULE FAILURE - CAPACITOR BANK FAULT
Replace power module.

Table 5-1. Flash Codes/DTC’s

FLASH CODE

DTC

HELP MESSAGE AND DESCRIPTION