Machine configuration programming information -18 – JLG M4069 ANSI Service Manual User Manual

Page 114

Advertising
background image

SECTION 5 - JLG CONTROL SYSTEM

5-18

– JLG Lift–

3121122

NOTE: When configuring an LE scissors machine, the machine configuration must be completed before any personality set-

tings can be changed. Changing the personality settings first and then changing the model number of the machine con-
figuration will cause the personality settings to return to default.

Table 5-4. Machine Configuration Programming Information

Configuration Digit

Number

Description

Default Number

0

1

2

3

4

5

1

(MODEL #)

0
1

3369LE
4069LE

0

2

(MARKET)

0
1
2
3
4
5

ANSI USA

ANSI EXPORT

CSA

CE

AUSTRALIA

JAPAN

0

3

(TILT CUTOUT)

0
1

NO - Drive & Lift Up not prevented when Tilted & Elevated

YES - Drive & Lift Up prevented when Tilted & Elevated.

1

1

1

0

1

1

4

(LEVELING JACKS)

0
1

NO - Leveling Jacks are not installed.

YES - Leveling Jacks are installed.

0

5

(CHARGER INTRLOK)

0
1

DRIVE - Drive is prevented when the vehicle is being charged.

DRIVE & LIFT - Drive & Lift Up are prevented when the vehicle is being

charged.

0

6

(GROUND ALARM)

0
1
2

NOT INSTALLED - The Ground Alarm shall not sound

DESCENT - The Ground Alarm shall sound during Lift Down

MOTION - The Ground Alarm shall sound during any vehicle motion.

1

1

1

1

1

2

7

(FUNCTION CUTOUT)

0
1
2

NONE

DRV & LFT UP - Only allows Lift Down when Function Cutout is active.

ALL FUNCTIONS - All functions are prevented when Function Cutout is

active

0

8

(4 WHEEL ASSIST)

0
1

NO - The 4 Wheel Assist option is not installed.

YES - The 4 Wheel Assist option is installed.

0

9

(LOAD)

0
1

2

NOT INSTALLED - Load Sensing System (LSS) is not fitted to the vehicle.

CUTOUT PLT - LSS is fitted, and Platform Controls are prevented in the

event of an Overload. Ground Controls remain functional. This is the

default setting for CE machines.

CUTOUT ALL - LSS is fitted. Platform and Ground Controls are

prevented in the event of an Overload

0

1

0

1

0

1

10

(TILT LIMIT)*

0
1

STANDARD - Normal tilt limits.

SPECIAL 1 - Vehicle tilt limits restricted to allow operation of a standard

3369LE in 16.7 m/s wind speeds for the CE Market.

NOTE: Tilt Limit selection is only visible for the 3369LE con-

figured for the CE Market. The selection will default
to STANDARD otherwise.

0

0

0

0

0

0

4150352_G