JLG M4069 ANSI Service Manual User Manual

Page 87

Advertising
background image

SECTION 4 - HYDRAULICS

3121122

– JLG Lift –

4-15

NOTE: Torque Locknut (8) to 400 ft lbs (542.3 Nm).

Torque Counter Balance Valve (20) and Check Valve
(21) to 30-35 ft. lb. (40-47 Nm).

When servicing, apply a light coat of grease to the
Jack Pad (2) before installing.

1

2

3

3

3

4

5

5

6

7

8

9

10

11

11

12

13

14

15

16

17

18

19

20

21

19

1. Cylinder Barrel
2. Jack Pad
3. Special Screw, 1/2" - 13NC x 1-1/4
4. Cylinder Rod
5. Retaining Ring
6. Plate
7. End Cap
8. Locknut
9. Piston

10. Flatwasher, 1-1/4"
11. Wear Ring
12. Piston Seal
13. O-Ring
14. Head
15. Wear Ring
16. O-Ring
17. Polyseal
18. Wiper Seal
19. Plug
20. Counter Balance Valve (see note)
21. Check Valve (see note)

Figure 4-13. Leveling Jack Cylinder - USA Built Machines S/N 0200112735 to Present)

Advertising