Oscillating Axle Lockout Test (If Equipped)

LOCKOUT SYSTEM TEST MUST BE PERFORMED QUARTERLY,
ANY TIME A SYSTEM COMPONENT IS REPLACED, OR WHEN
IMPROPER SYSTEM OPERATION IS SUSPECTED.

NOTE: Ensure platform is fully lowered prior to beginning

lockout cylinder test.

1. Place a 6 inch (15.2 cm) high block with ascension

ramp in front of left front wheel.

2. From platform control station, select LOW drive

speed.

3. Place DRIVE control switch to FORWARD position

and carefully drive the machine up ascension ramp
until left front wheel is on top of block.

4. Raise machine platform approximately 7 ft (2.1 m)

on the 3369LE or 9 ft (2.7 m) on the 4069LE.

5. Place DRIVE control switch to REVERSE position

and carefully drive the machine off the block and
ramp.

6. Have an assistant check to see that the left front

wheel remains locked in position off the ground.

7. Lower the machine platform; the lockout cylinder

should then release and allow wheel to rest on the
ground. It may be necessary to activate DRIVE to
release cylinders.

8. Place the 6 inch (15.2 cm) high block with ascension

ramp in front of right front wheel.

9. From platform control station, select LOW drive

speed.

10. Place DRIVE control switch to FORWARD position

and carefully drive the machine up ascension ramp
until right front wheel is on top of block.

11. Raise machine platform approximately 7 ft (2.1 m)

on the 3369LE or 9 ft (2.7 m) on the 4069LE.

12. Place DRIVE control switch to REVERSE position

and carefully drive the machine off the block and
ramp.

13. Have an assistant check to see that the right front

wheel remains locked in position off the ground.

14. Lower the machine platform; the lockout cylinder

should then release and allow wheel to rest on the
ground. It may be necessary to activate DRIVE to
release cylinders.

15. If the lockout cylinders do not function properly,

have qualified personnel correct the malfunction
prior to any further operation.