4 ground control circuit board, Software version 13.6, Ground control circuit board -19 – JLG M4069 ANSI Service Manual User Manual

Page 115: J1 connector -19

Advertising
background image

SECTION 5 - JLG CONTROL SYSTEM

3121122

– JLG Lift –

5-19

5.4 GROUND CONTROL CIRCUIT BOARD

Software Version 13.6

Table 5-5. J1 Connector

PIN

TAGNAME

FUNCTION

TYPE

1

PLTS

Platform Select

POWER

OUTPUT

2

PLTE

Platform EMS

POWER

INPUT

3

GND

Ground

POWER

OUTPUT

4

COL0

Column 0 Output

DIGITAL

OUTPUT

5

COL1

Column 1 Output

DIGITAL

OUTPUT

6

COL2

Column 2 Output

DIGITAL

OUTPUT

7

PCTL

Joystick Input (0 - 5VDC)

ANALOG

INPUT

8

ROW0

Row 0 Input

DIGITAL

INPUT

9

ROW1

Row 1 Input

DIGITAL

INPUT

10

COL3

Column 3 Output

DIGITAL

OUTPUT

11

COL4

Column 4 Output

DIGITAL

OUTPUT

12

COL5

Column 5 Output

DIGITAL

OUTPUT

13

ROW2

Row 2 Input

DIGITAL

INPUT

14

LCLK

LED Latch Clock Output

DIGITAL

OUTPUT

15

ALRM

Platform Alarm

DIGITAL

OUTPUT

16

IGN

Ignition Power (+12V; 750mA Limit)

POWER

OUTPUT

17

GALR

Ground Alarm

DIGITAL

OUTPUT

18

DO9

Spare High-Side Digital Output 9 (12V, 5A)

DIGITAL

OUTPUT

19

QPRX

Trigger Switch

POWER

INPUT

20

GNDE

Ground EMS (from J5-2; 500mA Limit)

POWER

OUTPUT

21

GINH

Generator Inhibit Start Switch

POWER

I/O

22

GND

Ground

POWER

OUTPUT

23

GND

Ground

POWER

OUTPUT

24

GND

Ground

POWER

OUTPUT

Advertising