J4 connector -22, J5 connector -22, J6 connector -22 – JLG M4069 ANSI Service Manual User Manual

Page 118

Advertising
background image

SECTION 5 - JLG CONTROL SYSTEM

5-22

– JLG Lift–

3121122

Table 5-8. J4 Connector

PIN

TAGNAME

FUNCTION

TYPE

1

12V

12V Sensor Supply

POWER

OUTPUT

2

TILTX

X-Axis Tilt Input (PWM)

ANALOG

INPUT

3

TILTY

Y-Axis Tilt Input (PWM)

ANALOG

INPUT

4

GND

Ground

POWER

OUTPUT

Table 5-9. J5 Connector

PIN

TAGNAME

FUNCTION

TYPE

1

B+

Master Supply Connection (from J2-1)

POWER

OUTPUT

2

GNDE

Ground EMS (to J1-20, J3-22)

POWER

INPUT

3

PLTS

Platform Select Input (to J1-1)

POWER

INPUT

4

GNDS

Ground Select Input

POWER

INPUT

5

IGN

Ignition Power (+12V)

POWER

OUTPUT

6

GND

Ground

POWER

OUTPUT

7

UPG

Ground Lift Up Switch

DIGITAL

INPUT

8

DNG

Ground Lift Down Switch

DIGITAL

INPUT

9

FDH

Full Drive Height Input

DIGITAL

INPUT

10

DI19

High-Sensing Digital Input 19

DIGITAL

INPUT

11

DI20

High-Sensing Digital Input 20

DIGITAL

INPUT

12

DI21

High-Sensing Digital Input 21

DIGITAL

INPUT

13

GMST

Generator Manual Start (to J3-19)

POWER

I/O

14

GFLT

Generator Fault LED (to J3-21)

POWER

I/O

15

HRMT

Hourmeter

DIGITAL

OUTPUT

Table 5-10. J6 Connector

PIN

TAGNAME

FUNCTION

TYPE

1

12V

Ignition Power (+12V)

POWER

OUTPUT

2

RX

RS-232 Serial Receive

SERIAL

INPUT

3

TX

RS-232 Serial Transmit

SERIAL

OUTPUT

4

GND

Ground

POWER

OUTPUT

Advertising