APPLICATION DATA — 566D150-240, 566E150-240 (cont)

REFRIGERANT PIPING SIZES

LEGEND

Close-coupled.

*Requires a double suction riser if 2 unloaders are used and the evaporator is

below the condensing unit. See Refrigerant Piping Sizes — Double Suction Ris-
ers table and Suction Line Piping figure below for more information.

NOTES:

1. Pipe sizes are based on a 2° F loss for liquid lines and a 1.5° F loss for suc-

tion lines.

2. Pipe sizes are based on an equivalent length equal to the maximum length

of interconnecting piping plus 50% for fittings. A more accurate estimate
may result in smaller sizes.

REFRIGERANT PIPING SIZES —

DOUBLE SUCTION RISERS

NOTES:

1. See Suction Line Piping figure below for “A,” “B,” and “C” dimensions.
2. No double suction risers are needed for unit size 240.

UNIT
566D

LINEAR LENGTH OF INTERCONNECTING PIPING (FT)

0-15

16-25

26-50

51-75

76-100

Line Size (in. OD)

L

S

L

S

L

S

L

S

L

S

150

1

/

2

1

1

/

8

1

/

2

1

3

/

8

5

/

8

1

3

/

8

5

/

8

1

5

/

8

*

7

/

8

1

5

/

8

*

180

1

/

2

1

3

/

8

5

/

8

1

3

/

8

5

/

8

1

5

/

8

7

/

8

1

5

/

8

7

/

8

2

1

/

8

*

240

5

/

8

1

5

/

8

5

/

8

1

5

/

8

7

/

8

1

5

/

8

7

/

8

2

1

/

8

7

/

8

2

1

/

8

UNIT
566E

LINEAR LENGTH OF INTERCONNECTING PIPING (FT)

0-25

25-50

50-75

75-100

Line Size (in. OD)

L

S

L

S

L

S

L

S

150

1

/

2

1

1

/

8

1

/

2

1

1

/

8

1

/

2

1

1

/

8

1

/

2

1

1

/

8

180

1

/

2

1

3

/

8

1

/

2

1

3

/

8

1

/

2

1

3

/

8

5

/

8

1

3

/

8

240

1

/

2

1

3

/

8

1

/

2

1

3

/

8

5

/

8

1

3

/

8

5

/

8

1

3

/

8

L — Liquid
S — Suction

UNIT
566D

LINEAR LENGTH OF INTERCONNECTING PIPING (FT)

51-75

76-100

Line Size (in. OD)

A

B

C

A

B

C

150

1

1

/

8

1

3

/

8

1

5

/

8

1

1

/

8

1

3

/

8

1

5

/

8

180

1

3

/

8

1

5

/

8

2

1

/

8

Location of One Liquid Line Solenoid

Valve Serving 2 Coil Circuits

(Solenoid Drop Control)

TXV — Thermostatic

Expansion Valve

TXV — Thermostatic

Expansion Valve

Face-Split Coil Suction and

Liquid Line Piping

LEGEND

Suction Riser

Without Trap

Suction Riser

With Trap

Suction Line to Condensing Unit

Short Vertical Riser Into Condensing Unit:

566D150,180 — 1

3

/

8

in. OD

A

B

C

D

Suction Line Piping

5

0TF

Q0

04-

0

1

2

56
6D

/E
150

-2
40

Advertising
This manual is related to the following products: