PERFORMANCE DATA (cont)

COMBINATION RATINGS (cont)

UNIT 576C120 (cont)

LEGEND

576C120/524A-C150 WITH HIGH-CAPACITY 4-ROW COIL

Temp (F)

Air Entering

Condenser

(Edb)

Evaporator Air — Cfm

3750

5000

6250

Evaporator Air — Ewb (F)

57

62

67

72

57

62

67

72

57

62

67

72

80

TC

122.0

125.0

135.0

147.0

133.0

133.0

141.0

153.0

141.0

141.0

145.0

157.0

SHC

122.0

117.0

97.7

77.1

133.0

133.0

113.0

86.9

141.0

141.0

127.0

96.0

kW

8.23

8.28

8.51

8.77

8.47

8.47

8.64

8.88

8.62

8.62

8.72

8.95

85

TC

120.0

122.0

132.0

144.0

130.0

130.0

138.0

149.0

138.0

138.0

142.0

153.0

SHC

120.0

116.0

96.5

76.0

130.0

130.0

112.0

85.6

138.0

138.0

126.0

94.7

kW

8.64

8.69

8.94

9.22

8.90

8.90

9.07

9.35

9.07

9.07

9.16

9.42

95

TC

115.0

116.0

126.0

137.0

125.0

125.0

131.0

142.0

132.0

132.0

135.0

145.0

SHC

115.0

113.0

93.9

73.6

125.0

125.0

109.0

83.2

132.0

132.0

123.0

92.3

kW

9.46

9.50

9.78

10.10

9.76

9.76

9.95

10.30

9.97

9.97

10.10

10.40

100

TC

113.0

113.0

123.0

134.0

122.0

122.0

128.0

139.0

129.0

129.0

131.0

141.0

SHC

113.0

111.0

92.6

72.4

122.0

122.0

108.0

82.0

129.0

129.0

121.0

91.1

kW

9.86

9.89

10.20

10.60

10.20

10.20

10.40

10.70

10.40

10.40

10.50

10.80

105

TC

110.0

111.0

119.0

130.0

119.0

119.0

124.0

135.0

126.0

126.0

128.0

138.0

SHC

110.0

109.0

91.4

71.1

119.0

119.0

107.0

80.8

126.0

126.0

120.0

89.9

kW

10.30

10.30

10.60

11.00

10.60

10.60

10.80

11.20

10.80

10.80

10.90

11.30

115

TC

105.0

105.0

113.0

123.0

114.0

114.0

117.0

127.0

120.0

120.0

121.0

130.0

SHC

105.0

105.0

88.8

68.7

114.0

114.0

104.0

78.4

120.0

120.0

117.0

87.4

kW

11.10

11.10

11.40

11.90

11.50

11.50

11.60

12.10

11.70

11.70

11.80

12.20

576C120/524A-B150 WITH STANDARD 3-ROW COIL

Temp (F)

Air Entering

Condenser

(Edb)

Evaporator Air — Cfm

3750

5000

6250

Evaporator Air — Ewb (F)

57

62

67

72

57

62

67

72

57

62

67

72

80

TC

115.0

118.0

129.0

140.0

125.0

126.0

134.0

146.0

132.0

132.0

138.0

149.0

SHC

115.0

110.0

92.3

73.1

125.0

125.0

106.0

81.7

132.0

132.0

119.0

89.6

kW

8.08

8.14

8.37

8.62

8.30

8.30

8.48

8.74

8.45

8.45

8.57

8.81

85

TC

113.0

116.0

126.0

137.0

123.0

123.0

131.0

142.0

130.0

130.0

134.0

146.0

SHC

113.0

109.0

91.1

71.9

123.0

123.0

105.0

80.5

130.0

130.0

117.0

88.5

kW

8.47

8.53

8.78

9.06

8.71

8.72

8.91

9.18

8.88

8.88

8.99

9.26

95

TC

109.0

110.0

120.0

131.0

118.0

118.0

124.0

136.0

124.0

124.0

128.0

139.0

SHC

109.0

106.0

88.7

69.6

118.0

118.0

102.0

78.2

124.0

124.0

114.0

86.1

kW

9.25

9.31

9.60

9.94

9.54

9.54

9.75

10.10

9.73

9.74

9.85

10.20

100

TC

106.0

108.0

116.0

127.0

115.0

115.0

121.0

132.0

121.0

121.0

124.0

135.0

SHC

106.0

104.0

87.5

68.5

115.0

115.0

101.0

77.0

121.0

121.0

113.0

84.9

kW

9.64

9.68

9.99

10.40

9.95

9.95

10.10

10.50

10.20

10.20

10.30

10.60

105

TC

104.0

105.0

113.0

124.0

112.0

113.0

118.0

129.0

118.0

118.0

121.0

131.0

SHC

104.0

103.0

86.2

67.3

112.0

113.0

99.7

75.8

118.0

118.0

111.0

83.8

kW

10.00

10.10

10.40

10.80

10.40

10.40

10.60

10.90

10.60

10.60

10.70

11.00

115

TC

99.2

99.3

107.0

117.0

107.0

107.0

111.0

121.0

113.0

113.0

114.0

124.0

SHC

99.2

99.3

83.7

64.9

107.0

107.0

97.1

73.5

113.0

113.0

108.0

81.4

kW

10.80

10.80

11.20

11.60

11.20

11.20

11.40

11.80

11.40

11.40

11.50

11.90

Edb — Entering Dry Bulb
Ewb — Entering Wet Bulb
kW

Compressor Motor Power Input

SHC — Sensible Heat Capacity (1000 Btuh) Gross
TC

Total Capacity (1000 Btuh) Gross

50
TF
Q

0

0

4

-0

1

2

5

6

9D

07
2-
12
0

, 57
6C

12
0

, 5

6

9F
1

2

0

Advertising
This manual is related to the following products: