Feedback cable port a and port b connector – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Eagle User Manual
Page 20
Advertising
![background image](/manuals/558366/20/background.png)
Gold Eagle Installation Guide
MAN-G-EAGIG-EC (Ver. 1.000)
||Basic Recommendations
20
9.2.2.
Feedback Cable Port A and Port B Connector
1.
On the motor side connections, ground the shield to the motor chassis.
2.
At least One COMRET (Common Return) must be connected to the PE.
Implement the following steps to connect the COMRET to the PE:
a.
At the drive, connect the feedback drain wire to one of the COMRET terminals in the
D-Type feedback connector (Figure 5).
b.
At the motor, connect the feedback cable drain wire to the GND motor chassis
terminal of the feedback connector.
The drawings below display two earth connections.
Figure 5: Feedback Port A and B Cable Assemblies
Advertising