Chapter 4: technical information, Environment conditions, Chapter 4 – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Eagle User Manual

Page 8: Technical information

Advertising
background image

Gold Eagle Installation Guide

MAN-G-EAGIG-EC (Ver. 1.000)

||Environment Conditions|

www.elmomc.com

8

Table of Contents

Chapter 4:

Technical Information

This chapter describes the relevant technical data applicable to the Gold Eagle servo drive. For
further details of the Gold ExtrIQ Line EMC and Safety standards, refer to the MAN-G-Panel
Mounted Drives Hardware Manual Chapter 15: Gold Line Standards.

4.1. Environment Conditions

The ExtrIQ products are designed, manufactured and tested to meet extreme environmental
conditions. The ExtrIQ durability is qualified, verified and tested according to the most severe
environmental, EMC and safety standards exceeding the traditional and senior military
Standards.

The ExtrIQ series of drives support the following extended environmental conditions.

Feature

Operation Conditions

Range

Ambient

Temperature

Range

Non-operating conditions

-50 °C to +100 °C (-58 °F to 212 °F)

Operating conditions

-40 °C to +70 °C (-40 °F to 160 °F)

Temperature

Shock

Non-operating conditions

-40 °C to +70 °C (-40 °F to 160 °F)
within 3 min

Altitude

Non-operating conditions

Unlimited

Operating conditions

-400 m to 12,000 m (-1312 to 39370 feet)

Maximum

Humidity

Non-operating conditions

Up to 95% relative humidity
non-condensing at 35 °C (95 °F)

Operating conditions

Up to 95% relative humidity non-
condensing at 25 °C (77 °F), up to 90%
relative humidity non-condensing at 42 °C
(108 °F)

Vibration

Operating conditions

20 Hz to 2,000 Hz, 14.6g

Mechanical

Shock

Non-operating conditions

±40g; Half sine, 11 msec, 3 per direction
(overall 18)

Operating conditions

±20g; Half sine, 11 msec, 3 per direction
(overall 18)

Advertising