Figure 24: Position command limits

Notes:

This tab does not set the counting range (modulo limits). You can define the

modulo limits in the setup window of the feedback sensor in the Conductor
Wizard. In an open loop stepping application the relevant modulo limits are
XM[1],XM[2].

The command limits must always be stricter than the feedback limit.
If the command limits are beyond the modulo limits they will be ignored.

3.3 Set up the Sensors

The drive may accept two sensors. Sensor #1 is for speed feedback and possibly
position feedback. The second feedback serves for position feedback, or as a
source for ECAM.

To set up the sensor, open the Conductor tool:

From the Composer, select the Wizard from the tools menu, or use the Wizard
button:

Figure 25: The Wizard button, encircled in red

This will open the Conductor window.