Database maintenance, 8 database, Maintenance – ElmoMC SimplIQ Digital Servo Drives-Bell Getting Started User Manual
Page 51: 8 database maintenance
![background image](/manuals/558371/51/background.png)
The SimplIQ for Steppers Getting Started & Tuning and Commissioning Guide
MAN-BELGS (Ver. 1.1)
51
3.8 Database Maintenance
Finally, save the results. Click the Database tab:
Figure 50: Database maintenance tab
Check the database integrity. This checks for certain conflicts that can prevent
the motor from starting. For example, if you selected a commutation finding
method by CA[17] that does not match the installed sensors, the motor will not
start and it will report "Bad Database". Checking the database here will prevent
this error.
Save your parameters in flash memory.
Restore your previously stored parameters from flash memory if you want to
purge your Conductor session.
The Expert List of this window brings up the entire SimplIQ database.