background image

The SimplIQ for Steppers Getting Started & Tuning and Commissioning Guide

MAN-BELGS (Ver. 1.1)

56

Although the automated frequency search works well in most cases, the
Conductor may miss very narrow resonance/anti-resonance pairs.

We recommend that you first let the Conductor identify with automated
frequency search.

Check Automatic Refinement to allow intensified resolution where the
frequency response changes rapidly, e.g. near resonant modes.

Make manual adjustments when:

The identification results do not look continuous and smooth enough.
You suspect, based on the evaluation results, that the Conductor missed a

resonance.

For this purpose, use the Frequency Editor.

Figure 53: Selecting the frequency editor

If you open the Frequency Editor before you have an identification result, the
window looks like this: