3.4. Connecting the Cables

3.4.1.

Wiring the Cymbal 

Once the Cymbal is mounted, you are ready to wire the device. Proper wiring, grounding and 
shielding are essential for ensuring safe, immune and optimal servo performance of the 
Cymbal. 

 

Caution: Follow these instructions to ensure safe and proper wiring: 

• Use twisted pair shielded cables for control, feedback and communication connections. For 

best results, the cable should have an aluminum foil shield covered by copper braid, and 
should contain a drain wire. 

The drain wire is a non‐insulated wire that is in contact with parts of the cable, usually 
the shield. It is used to terminate the shield and as a grounding connection. 

• The impedance of the wire must be as low as possible. The size of the wire must be thicker 

than actually required by the carrying current. A 24, 26 or 28 AWG wire for control and 
feedback cables is satisfactory although 24 AWG is recommended. 

• Use shielded wires for motor connections as well. If the wires are long, ensure that the 

capacitance between the wires is not too high: C < 30 nF is satisfactory for most 
applications. 

• Keep all wires and cables as short as possible. 

• Keep the motor wires as far away as possible from the feedback, control and 

communication cables. 

• Ensure that in normal operating conditions, the shielded wires and drain carry no current. 

The only time these conductors carry current is under abnormal conditions, when electrical 
equipment has become a potential shock or fire hazard while conducting external EMI 
interferences directly to ground, in order to prevent them from affecting the drive. Failing 
to meet this requirement can result in drive/controller/host failure. 

• After completing the wiring, carefully inspect all wires to ensure tightness, good solder 

joints and general safety. 