Cymbal Installation Guide

Installation

MAN-CYMIG (Ver. 1.3)

21

 

Figure 7: Non‐Isolated DC Power Supply 

The Power Supply is directly connected to the AC line (The AC must be limited to 135 VAC not 
to exceed the max 190 VDC in case of 200 VDC drive). 

The network PE must not be connected to the Return of the Power Supply. 
 

 

Figure 8: Non‐Isolated DC Power Supply 

The Power Supply is directly connected to the AC line through an Autotransformer. 

The network PE must not be connected to the Return of the Power Supply. 

 

Caution: Connecting the PE to the VN‐ with a non‐ isolated power supply will cause damages 
to the system (Any component that is connected to the system might be damaged). 