Cymbal thermal data, Heat dissipation data – ElmoMC SimplIQ Analog Servo Amplifiers-Cymbal User Manual

Page 30

Advertising
background image

Cymbal Installation Guide

Installation

MAN-CYMIG (Ver. 1.3)

30

3.7.1.

Cymbal Thermal Data 

• Free air convection thermal resistance (θ): Approximately 3.6 to 4 °C/W. 

• Thermal time constant: Approximately 40 minutes/ 2400 seconds (thermal time constant 

means that the Cymbal will reach 2/3 of its final temperature after 4 minutes). 

• Self heat dissipation capability (no external heatsink): 12 W for 40 °C/W temperature rise. 

• Shut‐off temperature: 86 °C to 88 °C (measured on the heatsink). 

• The thermal resistance when connecting to an external heat sink: 

ƒ The surface of the external heatsink is 50 μm: 0.18 °C/W. 
ƒ Thermal conductive compound. By proper Smearing of the surface a significant 

improvement of the thermal resistance is achieved: 0.13 °C/W  

3.7.2.

Heat Dissipation Data 

Heat Dissipation is shown in graphically below: 

Power Dissipation 60V series

0

10

20

30

40

50

60

70

80

90

100

0

12

20

30

40

50

60

70

80

90

Motor's Current (Ampere)

Pow

e

r D

is

s

ipa

ti

on

(

W

)

12VDC

20VDC

30VDC

40VDC

50VDC

56VDC

Heatsink

Required

Heatsink

not

Required

Standard 40

°C Ambient Temp.

 

 
 
 
 
 
 
 

www.elmomc.com

 

Advertising