Cymbal Installation Guide

Installation

MAN-CYMIG (Ver. 1.3)

29

3.6. DC Power Supply

The DC power supply can be at any voltage in the range defined in the technical specifications 
(Chapter 5 of this guide). The supply source must comply with the safety aspects of the 
relevant requirements, in accordance with the most recent version of the standard EN60950 or 
equivalent Low Voltage Directive Standard, all according to the applicable over‐voltage 
category. If the power source to the power supply is the AC line (through an isolated or a non
isolated transformer), safety margins must be considered, in order to avoid activating the 
undervoltage/overvoltage protection due to line variations and/or voltage drop under load. 

In addition to the above, the transformer must comply with the safety aspects of the relevant 
requirements in accordance with the most recent version of the standard EN 60742 (Isolating 
and Safety Isolating Transformers). The nominal DC bus voltage should be in the following 
range: 

 1.2 V

dcmin

 < Vdc < 0.9 V

dcmax 

Where: 
V

dcmin

 is the minimum DC bus 

V

dcmax

 is the maximum DC bus 

The transformer power should be calculated such that it will be able to deliver power to the 
amplifier (including peak power) without significant voltage drops. 

The power supply should be located as close as possible to the amplifier. While driving high‐
inertia loads, the power supply must be equipped with a shunt regulator; otherwise, the 
amplifier will be disabled whenever the capacitors are charged above the maximum voltage, 
during motor break down. 

 

3.6.1.

Powering Up 

After the Cymbal is connected to its devices, the Cymbal is ready to be powered up. 

 

Caution: Before applying power, ensure that the DC supply is within the specified range 
and that the proper plus‐minus connections are in order. 

3.6.2.

Initializing the System 

After the Cymbal has been connected and mounted, the system must be set up and initialized.  

3.7. Heat Dissipation

For full power output capability the Cymbal is designed to be mounted on an external heatsink. 
It is highly recommended that the “Wall” on which the Cymbal is mounted will have heat 
dissipation capabilities. The Cymbal at “free air convection” (without an additional heatsink) 
can dissipate around 12 W for 40 °C ambient temperature and not exceeding 80 °C on the 
heatsink.  

When “Free Air Convection” is sufficient for the application it is recommended to leave 
approximately 10 mm of space between the Cymbal's heatsink and any other assembly.  

www.elmomc.com

 