Power Dissipation 200V series

0

50

100

150

200

250

0

6.7

13.3

20.0

26.7

33.3

40.0

46.7

53.3

60.0

Motor's Current (Ampere)

Po

w

e

r Di

s

s

ip

a

ti

o

n

(W

)

40VDC

80VDC

120VDC

160VDC

196VDC

Heatsink

Required

Heatsink

not

Required

 

 

3.7.3.

How to Use the Charts 

The charts above are based upon theoretical worst‐case conditions. Actual test results show 
30% to 50% better power dissipation.  

To determine if your application needs a heatsink: 

1. Allow maximum heatsink temperature to be 80°C or less (shunt down is 6 °C to 8 °C 

higher). 

2. Determine the ambient operating temperature of the Cymbal as ≤ 40 °C. 

3. Calculate the allowable temperature increase as follows:  

For an ambient temperature of 40°C, ΔT= 80 °C – 40 °C = 40 °C  

4. Use the chart to find the actual dissipation power of the drive. Follow the voltage curve to 

the desired output current and then find the dissipated power.  

5. If the dissipated power is below 12 W the Cymbal needs no additional cooling. 

Note:

   The chart above shows that no heatsink is needed when the heatsink temperature is 

80 °C, ambient temperature is 40 °C and heat dissipated is 4 W. 

 