Control, i/os and halls cable assemblies – ElmoMC SimplIQ Analog Servo Amplifiers-Cymbal User Manual
Page 24
Cymbal Installation Guide
Installation
MAN-CYMIG (Ver. 1.3)
24
3.5.2.
Control, I/Os and Halls Cable Assemblies
The Cymbal features easy‐to‐use D‐Sub type connections for all Control, I/Os and halls cables.
Below are instructions and diagrams describing how to assemble these cables.
• Use 24, 26 or 28 AWG twisted‐pair shielded cables (24 AWG cable is recommended). For
best results, the shield should have aluminum foil covered by copper braid.
• Use only a D‐Sub connector with a metal housing.
• Attach the braid shield tightly to the metal housing of the D‐type connector.
• On the motor side connections, ground the shield to the motor chassis.
• On controller side connections, follow the controller manufacturer’s recommendations
concerning the shield.
Figure 10: Control, I/Os and Halls Cable Assemblies
Note:
All D‐Sub type connectors, used with the Cymbal, should be assembled in this way.
Metal Housing
Make sure that the braid shield is in tight
contact with the metal housing
www.elmomc.com