Control, i/os and halls cable assemblies – ElmoMC SimplIQ Analog Servo Amplifiers-Cymbal User Manual

Page 24

Advertising
background image

Cymbal Installation Guide

Installation

MAN-CYMIG (Ver. 1.3)

24

3.5.2.

 Control, I/Os and Halls Cable Assemblies 

The Cymbal features easy‐to‐use D‐Sub type connections for all Control, I/Os and halls cables. 
Below are instructions and diagrams describing how to assemble these cables. 

• Use 24, 26 or 28 AWG twisted‐pair shielded cables (24 AWG cable is recommended). For 

best results, the shield should have aluminum foil covered by copper braid. 

• Use only a D‐Sub connector with a metal housing. 

• Attach the braid shield tightly to the metal housing of the D‐type connector.  

• On the motor side connections, ground the shield to the motor chassis. 

• On controller side connections, follow the controller manufacturer’s recommendations 

concerning the shield. 

    

 

Figure 10: Control, I/Os and Halls Cable Assemblies 

Note:

 All D‐Sub type connectors, used with the Cymbal, should be assembled in this way.  

 
 

Metal Housing

Make sure that the braid shield is in tight 

contact with the metal housing

www.elmomc.com

 