Hawk Installation Guide

Installation

MAN-HAWIG (Ver. 1.401)

www.elmomc.com

54

Figure 31: RS-232 Connection Diagram

3.12.2. CAN Communication

Notes for connecting the CAN communication cable:

Connect the shield to the ground of the host (PC). Usually, this connection is soldered

internally inside the connector at the PC end. You can use the drain wire to facilitate
connection.

Ensure that the shield of the cable is connected to the shield of the connector used for

communications. The drain wire can be used to facilitate the connection.

Make sure to have a 120-Ω resistor termination at each of the two ends of the network

cable.

The Hawk’s CAN port is non-isolated.

Pin (J1) Signal

Function

Pin Positions

30

CAN_GND

CAN ground

31

CAN_L

CAN_L busline (dominant low)

32

CAN_H

CAN_H busline (dominant high)

Table 11: CAN - Pin Assignments