CEM3 may be used as a control module in ETC's FDX3000 dimming system, providing

networking facilities, dual redundant control modules, and precision 16-bit dimming. This

appendix details information needed to work with CEM3 in an FDX3000 system, as well as

outlining the hardware of your FDX3000 rack.

Hardware

Front Panel

The FDX3000 carrier contains two CEM3 modules in a dual redundant configuration.

PSU Indicators

The PSU indicators show the status of the two internal power supplies which supply the

15VDC required by FDX dimmer modules.

The two indicators should be lit at all times. If either is not lit, this could indicate a failure of

the internal power supply. If you see this condition, contact ETC Technical Services (see

page 3

).

Redundant Tracking Switch

The redundant tracking switch allows you to test the ability to switch from the upper (A)

processor to the lower (B) processor. If it is set to the (A) or (B) position, the A or B

processor will preferentially have control. In normal operation, the switch should be set to

the center “Auto” position. This will ensure that A has control unless communication is lost

to A, or certain hardware failures occur on A but not B (for example if A does not see DMX

but B does).