Setting up patch, Automatic patch, Simple – ETC CEM3 v1.5.1 User Manual

Page 43: Split, Independent

Advertising
background image

3

Common Tasks

37

Setting Up Patch

Patch governs the relationship between control sources (DMX A, DMX B, and sACN) and

the rack’s circuits and is editable from the CEM3 face panel. Typically, repatching is used

in portable rack situations where the dimmer rack must adapt to different control sources

and lighting systems. For permanent rack installs, altering your patch is rarely needed.

Racks with only one assigned space can have their patch edited through one of two

methods: Manual or Automatic. Racks with multiple assigned spaces can only be edited

manually. For racks edited using an automatic method, circuits will be numbered

sequentially from the specified starting address following the designated “Straight” or

“Balanced” setting in Quick Setup.

Any circuit set to a patch of “0” will render that circuit uncontrollable from the data source

specified.

Automatic Patch

When you chose an automatic patching method the entire rack will be patched sequentially

based on the criteria of the chosen option in Quick Setup. Only racks with one assigned

space can use these methods.

If dimmer doubling is enabled, you will see additional fields for addressing dimmer doubled

circuits.

There are three options offered for automatic patching: Simple, Split, and Independent.

Simple

This patching method specifies the same starting circuit for all three data ports (DMX A,

DMX B, and sACN) at once. Enter the starting number for the patch. Universe size is 512

dimmers (256 if dimmer doubling is enabled). If the patch count exceeds 512, the patch will

“wrap” and start numbering again at 1 (257 for dimmer doubling).

Split

This patching method should be used when a DMX universe will end part way through the

rack’s patch. Enter the starting number for the patch. If the patch sequence exceeds 512

(256 if dimmer doubling is enabled) DMX A will patch the rest of the circuits to “0” and DMX

B will restart the patch numbers at 1 for those remaining circuits.

Independent

This method allows you to specify different starting numbers for each data port in the patch

(DMX A, DMX B, and sACN). Select a data port and assign the desired starting address for

the rack. If the rack count then exceeds 512 (for DMX ports) the remainder of circuits in the

rack will be patched to zero for that DMX port.

To set an automatic patching method:

Step 1:

Navigate to [Setup]>Patching>Automatic: <choose method>.

Step 2:

Enter or scroll to the desired starting channel number using the keypad. For

Independent Mode, repeat for the other data ports.

Step 3:

Press [Enter] and confirm to save the changes.

N o t e :

Module density can affect patching. Prior to patching, make sure you set up the

module type in [Setup]>Circuit Assignment.

Advertising