FDX 3000 Dimmer Racks

59

FDX2000 vs. FDX3000 Dimmer Curve Comparison

Curves in FDX3000 reference voltage rather than power. Therefore the following table will

help to show the correlation between FDX2000 curve names and FDX3000 curve names.

.

FDX2000 Curve

English / German

FDX3000 Curve

English

Comment

1 = Linear (default)

Square

proportional to RMS power output (FDX2000 Linear)

2 = Stage1

Stage 1

Built to match an old Siemens curve

3 = Stage2

Stage 2

Built to match an old Siemens curve

4 = Log

Linear

proportional to RMS voltage output

5 = Fluor1

Fluor 1

6 = Fluor2

Fluor 2

7 = Pow/2

n.a.

obsolete

8 = 10%

n.a.

obsolete

9 = VIP90

VIP

10 = ANDI

ANDI

n.a

Mod-Square (Default)

n.a

Mod-Linear

n.a

Sensor 2.0

older mod square law