Product description – Lenze I/O system 1000 System Manual User Manual

Page 214

Advertising
background image

Product description

I/O compound modules − encoder evaluation
SSI − EPM−S604

3

l

214

EDSIO1000 EN 7.0

Operating modes

In the "Master mode"the module is directly connected to an SSI encoder and also supplies
it. For reading out the encoder, the module provides a cycle to the encoder and presents the
received data current in the process image.

Dead time

Shift register

Baud rate

Data stream

MSB last/first

Scaling

bits

Bit length

encoder data

Scaling

Coding

Standard

Gray

... 10101010111010100011

... 10101010111010100011

1,1101010001e+011

Process image

Clock generator

Encoder

SSI module (master mode)

SLIO048

Fig. 3−71

"Master mode" block diagram

In "Monitoring operation"the monitoring module is operated on an SSI encoder passively
to the master module. During this operating mode the SSI encoder has to be supplied via
the master module. During operation, the module monitors the signals of the SSI telegram
and provides the data flow in the process image. In this case again, the module has to be
adapted to the corresponding encoder via parameterisation. The "Baud rate" parameter is
irrelevant.

Dead time

Shift register

MSB last/first

Scaling bits

Bit length -

encoder data

Scaling

Coding

StandardGray

... 10101010111010100011

... 10101010111010100011

Process image

Clock evaluation

Data stream

Encoder

SSI module (monitoring operation)

SSI module (master mode)

111010100011

SLIO049

Fig. 3−72

"Monitoring operation" block diagram

Advertising