Preconditions – Lenze E70ACxS Application Sample i700 (PLC Designer v3) User Manual

Page 10

Advertising
background image

Preconditions

Setting up communication to the Controller

10

Lenze · Servo Inverter i700 | Application Sample · DMS 1.0 EN - 09/2012 - TD11

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

• Enter the desired IP address of the Controller.

[3-1]

Example: Enter the IP address of the Controller

3. Click OK to add the Controller as gateway.
4. By double-clicking the desired channel (or clicking the Set active path button) set the

channel selected in the Device View below the gateway as active path for control.

• Thus, all communication actions directly refer to this channel.
• The currently active path is represented in bold in the list and "(active)" is attached:

5. A device represented in italics is set as active path but has not been identified during the

last network scan.

Note!

• During initial commissioning, observe the following predefined IP addresses of the

Controllers: 192.168.5.99

Further information can be found in the following documentation:

Controller - Parameter setting & Configuration