7 coupling/decoupling of an axis: "gearingaxisy, Coupling/decoupling of an axis: "gearingaxisy, Getting started - operating the application sample – Lenze E70ACxS Application Sample i700 (PLC Designer v3) User Manual

Page 28

Advertising
background image

Getting started - operating the Application Sample

Coupling/decoupling of an axis: "GearingAxisY"

28

Lenze · Servo Inverter i700 | Application Sample · DMS 1.0 EN - 09/2012 - TD11

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.7

Coupling/decoupling of an axis: "GearingAxisY"

How to proceed:

1. Click the GearingAxisY button.
2. Enable the controller: Click the xRegulatorOn button.
3. Start the positioning process: Click the xStart button.
4. Set the acceleration/deceleration: Enter the desired values in MC_GearIn.
5. Set the desired deceleration of MC_Halt.
6. Coupling/decoupling

• Start "Coupling": Click Execute in MC_GearIn.
• "Decoupling": Click Execute in MC_GearOut.

7. To bring Axis Y to a standstill after decoupling, click Execute in MC_Halt.

The parameters of the function blocks can be edited anytime directly in the

visualisation.