MTS Landmark TWX User Manual

Page 124

Advertising
background image

1. Add a rule.

Click the green + sign in the upper right corner of the Configure Autotag Rules window.

2. Enter a variable.

Click the Variables tab, and then select PeakStress from the list. PeakStress appears in the
Calculation panel.

3. Enter a function and a value.

In the Calculation panel, enter PeakStress>1250000000 immediately following PeakLoad.

4. Enter an error message.

Enter >1.25 kN/(mm²) in the Error Message text box.

5. Click Close.

124 | MTS Landmark Test System Operation

Reviewing, Analyzing, and Reporting Data

Advertising