MAYCO LS300P CONCRETE PUMP • OPERATION MANUAL — REV. #0 (06/09/14) — PAGE 23

PUMP COMPONENTS

Figure 5 and 6 illustrates the location of the major

components for the LS300P Concrete Pump. The function

of each component is described below:
1.

Tires — This trailer uses two ST205-750 x15E type

tires. Tire inflation pressure is the most important factor

in tire life. Pressure should be checked to

50 psi cold

before operation.

DO NOT bleed air from tires when

they are hot. Check inflation pressure weekly during

use to insure the maximum tire life and tread wear.

2.

Zerk Grease Fittings — Top fitting lubricates shuttle

cylinder top, center position lubricates nun plate and

bottom position lubricates shuttle cylinder bottom.

3.

Hydraulic Oil Sight Glass — Use to determine the

amount of hydraulic oil remaining in tank. The sight

glass also contains a temperature gauge for monitoring

the temperature of the hydraulic oil.

4.

Hydraulic Oil Tank/Cap — Remove cap to add

hydraulic fluid. Fill with Shell Oil Tellus 68 or Mobil Oil

DFE26 if level is low.

5.

Hydraulic Oil Filter — This in-tank return hydraulic

filter with a 10 micron cleanable filter is designed to

remove all particles large enough to cause wear and

job break down. Under normal conditions, clean every

6 months.

6.

Air Filter — Prevents dirt and other debris from

entering the fuel system. Release the latches on the

side of the air filter cover to gain access to filter element.

NOTICE

Operating the engine without an air filter, with a damaged

air filter, or a filter in need of replacement will allow dirt to

enter the engine, causing rapid engine wear

7.

Muffler — Used to reduce noise and emissions.

NEVER touch the muffler while it is hot! Serious burns

can result.

NEVER operate the engine with the muffler

removed.

8.

Radiator — Fill only with recommended coolant.

Radiator coolant capacity is 4.5 gallons (17 liters).

9.

Documentation Box — Contains engine and pump

operation, parts and maintenance information.

10.

Breakaway Switch/Cable — Used in conjunction with

the hydraulic actuator. Connect to tow vehicle.

11.

Tow Hitch Coupler — Requires a 2-inch ball hitch or

a 3-inch pintle. Capable of towing 6,000 lbs.

12.

Safety Chains — This pump uses 5/16-inch thick,

72 inches long zinc-plated safety chains.

ALWAYS

connect safety chains when towing. ALWAYS cross

chains when connecting to tow vehicle.

13.

Hydraulic Actuator — This actuator will be activated

in the event of a breakaway. The breakaway cable must

be rigged to the tow vehicle with appropriate slack

that will activate the system if the coupler connection

comes loose.

14.

Lubrication Box — This box is empty when shipped

from the factory. Please fill with 3 gallons (11.35 liters)

of SAE 30 motor oil for first time use. Also check the

dual clean-out point on bottom of lubrication box for a

secure tight fit.

15.

Heat Exchanger — Reduces temperature of the

hydraulic oil. The exchanger draws oil from the

hydraulic system into the heat exchanger before

allowing it to flow back into the reservoir.