MAYCO LS300P CONCRETE PUMP • OPERATION MANUAL — REV. #0 (06/09/14) — PAGE 27

DIGITAL CONTROL PANEL COMPONENTS

PRIMARY SCREEN

Screen 1

Indicates the various modes of the switch settings. Monitors

engine RPM - Idle speed 900, High speed 2350. Battery

charge indicator - Normal charge 13+ volts. Indicates

electrical malfunction - Refer to Troubleshooting section.

SECONDARY SCREENS

Screen 2

Displays the status of the shuttle cylinder proximity switches.

Screen 3

Displays the number of hours the engine and pump

have been used and the number of faults the pump has

registered. All three indicators can be reset to zero by the

RESET switch on the control panel.

Screen 4

Displays the number of strokes the main hydraulic cylinders

have gone through. This indicator can be reset to zero by

the

RESET switch on the control panel.

LS 300 OFF

0000 ENG RPM

BATTERY 12.5 V

LOW OIL PSI

1

INDICATES

STATUS OF PUMP

( ON OR OFF)

INDICATES

ENGINE RPM

INDICATES

BATTERY

CHARGE

INDICATES

ELECTRIC

MALFUNCTION

PROX

C

OFF

PROX

D

OFF

2

INDICATES PROX

C OFF

INDICATES PROX

D OFF

E HRS: 00000.0

PMP HRS: 00000.0

FAULTS: 00000000

RESET TO CLEAR

3

INDICATES NO.

OF HOURS

ENGINE HAS

BEEN USED

MESSAGE OR

INSTRUCTION

INDICATES NO.

OF HOURS

PUMP HAS

BEEN USED

INDICATES

CODE

STROKE CTR: 0000

PRESS RESET TO

ZERO STROKE CTR

4

INDICATES A

RUNNING

COUNT OF

NO. OF STROKES

READ EVEN

NUMBER ONLY

MESSAGE OR

INFORMATION

Screen 5

Displays the ON/OFF electrical signal status of the various

12 volt solenoids (Swing A circuit, Main A circuit, Main B

circuit).

Screen 6

Displays the ON/OFF electrical signal status for the

Proximity Switch A, Proximity Switch B, Engine Fuel

Solenoid, and Unloader Solenoid.

Screen 7

Displays the number of times the main hydraulic cylinders

stroke and the yards per hour output. This indicator can

be reset to zero by the

RESET switch on the control panel

Screen 8

Displays the electrical status of the engine fuel solenoid. To

test the 12-Volt solenoid status, activate with the

RESET

switch on the control panel.

Screen 9
Displays the communication status of the (optional) radio

remote control. To activate a new remote control connection,

use the reset switch on the control panel.

INDICATES

SWING A

CIRCUIT IS OFF

INDICATES

MAIN A

CIRCUIT IS OFF

INDICATES

MAIN B

CIRCUIT IS OFF

SWING A OFF

SWING B OFF

MAIN A OFF

MAIN B OFF

5

INDICATES

SWING B

CIRCUIT IS OFF

INDICATES

PROXIMITY A

CIRCUIT IS OFF

INDICATES

PROXIMITY B

CIRCUIT IS ON

INDICATES

FUEL SOLENOID

CIRCUIT IS OFF

PROX A OFF

PROX B ON

FUEL SOL OFF

6

INDICATES

THROTTLE

IS ON

INDICATES THE

NUMBER OF

STROKES

INDICATES THE

NO. OF STROKES

PER MINUTE

INDICATES THE

NO. OF YARDS

PER HOUR

THROTTLE ON

STROKES: 20

STROKES/MIN 8.2

YDS/HR 10.7

7

INSTRUCTION

OR MESSAGE

INDICATES THE

FUEL SOLENOID

IS OFF

TO TEST FUEL

SOL PRESS RESET

FUEL SOL OFF

8

INDICATES

THAT RADIO

REMOTE IS ON

IINSTRUCTION

OR MESSAGE

RADIO ADDRESS

COMMUNICATING

PRESS RESET TO

LEARN A NEW ONE