Maintenance – Multiquip LS-300P User Manual

Page 51

Advertising
background image

MAYCO LS300P CONCRETE PUMP • OPERATION MANUAL — REV. #0 (06/09/14) — PAGE 51

Long Term Storage (Pump)

„

Remove the battery.

„

Drain the fuel tank completely. Treat with a fuel stabilizer

if necessary.

„

Clean exterior with a cloth soaked in clean oil.

„

Store unit covered with plastic sheet in moisture and

dust-free location out of direct sunlight.

Long Term Storage (Trailer)

1. Check brake system for proper fluid level in master

cylinder and bleed all lines.

2. Lubricate all links and pivots to prevent any rusting.
3. Remove wheel and drum assemblies and spray a good

anti-corrosion compound (CRC formula 5-56) under

rubber boot on forward end of brake wheel cylinder.

Avoid spraying drum and brake lining.

4. Grease all bearings and reinstall wheel and drum

assemblies.

5. Make sure breakaway cable is fully released.
6. After extended storage, refer to the Maintenance Steps

listed above to insure that the trailer is ready for towing.

CAUTION

NEVER store the pump with fuel in the tank for any

extended period of time.

ALWAYS clean up spilled

fuel immediately.

MAINTENANCE

Advertising