TROUBLESHOOTING (PUMP)

Troubleshooting (Pump)

Symptom

Possible Problem

Solution

Main Hydraulic Cylinder will

not cycle

Incorrect System Operating Pressure Check the pump pressure gage. Verify it is

approx. 3100 — 3200 PSI

Incorrect Engine RPM setting

Verify the engine's high RPM speed is set to

2550

Contaminated Main Relief Valve

Check the manifold for a contaminated Relief

Valve

Obstructed Material Cylinders

Check for obstructions (dried material) inside

the cylinders

Shuttle Cylinder slow to

complete stroke

Improper Flow Control setting

Fully open Flow Control Valve

Incorrect Engine RPM setting

Verify the engine's high RPM speed is set to

2550

Incorrect Main Hydraulic

System Operating Pressure

Check the pump pressure gage. Verify it is

approx. 3200 PSI

Hopper Discharge Nipple Seal

improperly lubricated

Check the Hopper Discharge Nipple Seal for

seizing and lack of lubricant

Concrete slurry in

lubrication box

Worn or defective urethane cups or

worn material cylinder

Replace

Material cylinder piston

cups squeal

Low on lubrication

Check oil level

Battery voltage falls below

12VDC on digital display,

causing engine not to start

Blown out Fuse

Check the fuse

Dead battery

Check the charge on the battery

Wiring connection inside Control Box Check the wiring connections and verify power

is reaching ignition switch