PAGE 78 — MAYCO LS300P CONCRETE PUMP • OPERATION MANUAL — REV. #0 (06/09/14)

TROUBLESHOOTING (ELECTRICAL)

Troubleshooting (Electrical)

Malfunction Reading (Screen 1)

Possible Problem

Solution

Main A OPEN

Burnt 12 V cycling solenoid.

Measure solenoid coil resistance. It should read 6
ohms. Replace burnt solenoid.

Wire connection broken.

Replace broken wire.

Main A SHORTED

The 12-volt cycling solenoid is shorted

directly to ground.

Measure solenoid coil resistance. It should read 6
ohms. Replace shorted solenoid.

Wire connection is shorted directly to the
ground.

Correct connection.

Main B OPEN

Burnt 12 V cycling solenoid.

Measure solenoid coil resistance. It should read 6
ohms. Replace burnt solenoid.

Wire connection broken.

Replace broken wire.

Main B SHORTED

The 12-volt cycling solenoid is shorted
directly to ground.

Measure solenoid coil resistance. It should read 6
ohms. Replace shorted solenoid.

Wire connection is shorted directly to the
ground.

Correct connection.

Swing OPEN

Burnt 12 V cycling solenoid.

Measure solenoid coil resistance. It should read 6
ohms. Replace burnt solenoid.

Wire connection broken.

Replace broken wire.

Swing SHORTED

The 12-volt cycling solenoid is shorted
directly to ground.

Measure solenoid coil resistance. It should read 6
ohms. Replace shorted solenoid.

Wire connection is shorted directly to the
ground.

Correct connection.

Fuel solenoid open

Burnt 12 V cycling solenoid.

Measure solenoid coil resistance. It should read 6
ohms. Replace burnt solenoid.

Wire connection broken.

Replace broken wire.

Fuel solenoid shorted

The 12-volt cycling solenoid is shorted
directly to ground.

Measure solenoid coil resistance. It should read 6
ohms. Replace shorted solenoid.

Wire connection is shorted directly to the
ground.

Correct connection.

Proximity switch C

Digital Control Box not sending signal.

Check screen #5 for operational status.

Shuttle cylinder short stroking not
energizing proximity sensor.

• Misaligned hopper
• Discharge nipple seizing
• Hopper outlet requires lubrication

Proximity switch D

Digital Control Box not sending signal.

Check screen #5 for operational status.

Shuttle cylinder short stroking not
energizing proximity sensor.

• Misaligned hopper
• Discharge nipple seizing
• Hopper outlet requires lubrication