Digital control panel components, Figure 7. pump digital control panel components – Multiquip LS-300P User Manual

Page 26

Advertising
background image

PAGE 26 — MAYCO LS300P CONCRETE PUMP • OPERATION MANUAL — REV. #0 (06/09/14)

DIGITAL CONTROL PANEL COMPONENTS

Figure 7 displays the components associated with the

digital control panel. A brief description of each component

is described below
1.

Scroll Switch — Allows the operator to scroll the

various readout screens.

2.

Reset Switch — Allows the operator to reset the

stroke counter.

3.

Digital Readout Screen — Displays and monitors the

various functions of the machine.

4.

Emergency Stop Button — Press emergency stop

button to stop pump in an emergency. Turn knob

counterclockwise to disengage the stop button.

5.

Ignition Switch — Insert the ignition key here to start

the engine. Turn the key clockwise to the ON position,

then continue turning clockwise to the START position

and release. To stop the engine turn the key fully

counterclockwise to the STOP position.

6.

Pumping Control Switch — This 3-position switch

controls the pumping of the pump. The

rightmost

position (REMOTE) is for use with the remote control

unit, the

leftmost position (LOCAL) is for normal

pumping operation, and the

centermost position

(CENTER OFF) prevents pumping.

7.

Remote Cable Connector — Insert the remote control

input cable into this connector.

8.

Manual Cylinder Jogging Switch — This 2-position

switch allows the operator to manually jog the cylinders

to assist in clearing material line packs and is used to

test pumping pressure (See

Initial Start-up Procedure

section of this manual for testing procedure).

The leftmost position jogs Cylinder (A) and the

rightmost position jogs Cylinder (B).

9.

Cylinder Stroke Control Switch — This 2-position

switch controls the pumping function. The

leftmost

position (AUTOMATIC) sets the pump to automatic

cycling. Set the switch to this position for normal pump

operation.

The

rightmost position (JOG) changes the pump from

automatic to

manual cycling. This allows the cylinders

to be manually cycled using the

Manual Cylinder

Jogging Switch.

10.

Direction Control Switch — This 2-position switch

controls the direction of flow for any mix in the pump.

The

leftmost position sets the pumping direction to

forward and the rightmost position sets the pumping

direction to reverse.

11.

Main Pressure Gauge — This gauge monitors

the system pressure while pumping material. The

maximum pressure rating is 3100 PSI ± 50.

Figure 7. Pump Digital Control Panel Components

0

5

0

0

7

5

0

1000

12

5

0

1

5

0

0

2

0

0

0

PUMPING

PRESSURE

4

5

1

2

7

8

9

10

3

6

11

OFF

ON

IGNITION

REMOTE

CONTROL

FLOW

DIRECTION

LOCAL

FORWARD

AUTOMATIC

JOG

RESET

SET

SCROLL

JOG “A”

CYLINDER STROKE

JOG “B”

REVERSE

CENTER

OFF

REMOTE

START

E

m

erg

ency S

top

Advertising