Radio Remote Control Buttons Operation

Before the remote control hand-held module can be used,

the

pumping control switch on the control box must be

placed in the

REMOTE position (Figure 34).

Figure 34. Pumping Control Switch (Remote)

Remote pumping operation can be performed by the hand-

held radio remote control module (Figure 35).

Figure 35. Radio Remote Control

The buttons on the hand-held remote control module have

the following functions:

„

ON/OFF – Turns the power on or off. When power is on

the power LED lights red. If the battery LED turns red,

9V battery needs to be replaced.

„

E-STOP – Turns off the pump completely in an

emergency.

LOCAL

REMOTE

CENTER

OFF

E-STOP

ON

OFF

PUMP

REV

VOLUME

VOLUME

PUMP

ON/OFF

POWER LED

NOTE: OLDER MODELS
MAY INDICATE
INSTEAD OF

FLOW

VOLUME

BATTERY LED

„

PUMP ON/OFF – Starts and stops the forward pumping.

„

PUMP REV – momentarily pumps in reverse direction.

„

VOLUME (+) – used to increase the pumping volume.

„

VOLUME (-) – used to decrease the pumping volume.

Radio Remote Control Programming

Before starting operation of the hand-held

radio remote

control, go to Screen 9 of the digital readout screen:
Screen 9

1. Press the

ON/OFF button on the radio (wireless)

remote control to turn on the power. Hold down the

RESET switch. The display will now show.

Screen 9

2. After 5 seconds, the display will show:
Screen 9

3. The hand-held remote control module is now ready

for use.

RADIO ADDRESS

NO RADIO

PRESS RESET TO

LEARN A NEW ONE

9

RADIO ADDRESS

NOW SCANNING

FOR NEW

TRANSMITTER

9

RADIO ADDRESS

COMMUNICATING

PRESS RESET TO

LEARN A NEW ONE

9

OPERATION