PUMP COMPONENTS (CONTINUED)

16.

Hopper/Hood — Lift hood to fill. Concrete from a Redi-

Mix truck is poured into this hopper. The hopper can

hold 10 cu. ft of concrete. NEVER put hands or any

other parts of you body into the hopper.

17.

Hydraulic Oil Reservoir Access Cover — Remove

this cover to gain access to the hydraulic oil tank for

maintenance/cleaning.

18.

Fuel Cap — Remove this cap to add fuel. Fill with No. 2

diesel fuel. DO NOT top off fuel. Wipe up any spilled

fuel immediately.

19.

Manifold Access Door — Release latch and lift door

to access the hydraulic manifold block.

20.

Control Box — Contains the electrical components

required to run the pump. See Control Box Components

section for component callouts.

21.

Oil Filter — Prevents dirt and other debris from entering

the engine. Service the oil filter as recommended in the

maintenance section of this manual.

22.

Engine Throttle Lever — Controls the speed of

the engine. For load conditions (pumping concrete)

ALWAYS run the engine at full speed.

23.

Fuel Water Separator Filter — Prevents sediments,

water and other debris from entering the fuel system.

Service the fuel filter as recommended in the

maintenance of this manual.

24.

In-Line Fuel Filter — Replace or clean fuel filter as

specified in the maintenance section of this manual.

25.

Hydraulic Pump — This unit incorporates an axial

variable displacement hydraulic piston pump.

26.

Pumping Pressure Gauge — Used to monitor

pressure in the concrete cylinders and shuttle tube.

27.

Stroke Volume Control Knob — Turns CW/CCW to

increase or decrease the number of strokes per minute

of the pump.

28.

Rear Running Lights ALWAYS check and make

sure both the right and left running lights are functioning

correctly before towing the pump

29.

Pump End Jack Stand — Use this jack stand to

support the rear end of the pump. NEVER deploy on un-

level ground and always check for firmness of ground.

30.

Hopper Discharge Outlet — Connect hoses or steel

pipes to the discharge sleeve for pouring concrete.

31.

Radio Control Antenna — Mounting location for radio

control antenna. Works in conjunction with hand-held

radio remote (option).

32.

Hydraulic Oil Reservoir — Holds 33 gallons (125

liters) of hydraulic oil.

33.

Hydraulic Manifold Block — Manifold block

that controls the flow of hydraulic pressure to the

components required to control the pump.

34.

Fuel Line Guard/Fuel Gauge — Protects the fuel line

from damage. The fuel line (tube) also serves as a fuel

gauge. To determine when fuel is low visually read the

level of fuel shown on the fuel line.

35.

Fuel Tank — Holds 16 gallons (61 liters) of diesel fuel.

36.

Shuttle Cylinder/Guard — Under pressure, the

shuttle cylinder shears concrete passing from the

concrete cylinder to the delivery line during the cycle

phase.

ALWAYS keep hands clear from shuttle cylinder

during operation.

37.

Battery — This unit uses a +12 VDC type battery.

ALWAYS use gloves and eye protection when handling

the battery.

38.

Tow End Jack Stand — Use this jack stand to level

and support the tow end of the pump.