2 Installation

All connections to the module should be SELV only. Normal 110/220/240V mains

supply should not be connected to any input terminal of the module.

2.1 General installation
Several WI-I/O-EX modules may be connected to one master via RS485 multi-drop

connection as shown in Figure 2-1. Ensure there is good grounding between the WI-I/O-

EX units and the master. A 2.5 mm

2

/ 12 gauge earth wire is recommended.


Figure 2-1: Several WI-I/O-EX units connected to a master.

2.1.1 Power Connection
The WI-I/O-EX modules require a 10.8-30 VDC ** power supply. This is supplied to the

4-way connector, shown in Figure 2-2.


Figure 2-2: Power and RS485 connector. Connect 10.8-30 VDC** to + and earth to -.

Connect RS485 to B and A.

** Model Dependent. Check rear label for actual operating voltages

2.1.2 Address Switches
The address switches are found on the bottom panel of the module, as shown in Figure

2-3. If you are using the WI-I/O-EX module with other modules WI-I/O 9, WI-MOD-9-E

and WI-MOD-E modules), the address switches must be set to “00”. This enables E-

Series protocol mode.

If you are using a ModBus Master device, ensure each WI-I/O-EX connected to the same

ModBus master has a unique ModBus address.

Note that the module must be reset after changing the address switches.