Chapter 5

Programming Parameters

5-13

Parameter 558 – [A > Digital Out 1]
Parameter 508 – [B > Digital Out 1]

Use : Maps Digital Output 1
Programming Terminal units: None
Minimum Value: 0 (#1), 16 (#2)
Maximum Value: 15 (#1), 31 (#2)
Default Value: 10
Description: This parameter determines which bit of one of the two
Digital Output fast parameters will control Digital Output 1. Entering a
bit value of 0 – 15 will cause the Digital Output 1 (par 450) to control
digital out 1. Entering a bit value of 16 – 31 will cause the Digital
Output 2 (par 454) to control digital out 1. When the bit value is 1, this
output will be high.

Parameter 559 – [A > Digital Out 2]
Parameter 509 – [B > Digital Out 2]

Use : Maps Digital Output 2
Programming Terminal units: None
Minimum Value: 0 (#1), 16 (#2)
Maximum Value: 15 (#1), 31 (#2)
Default Value: 5
Description: This parameter determines which bit of one of the two
Digital Output fast parameters will control Digital Output 2. Entering a
bit value of 0 – 15 will cause the Digital Output 1 (par 450) to control
digital out 1. Entering a bit value of 16 – 31 will cause the Digital
Output 2 (par 454) to control digital out 1. When the bit value is 1, this
output will be high.

Parameter 560 – [A > Digital Out 3]
Parameter 510 – [B > Digital Out 3]

Use : Maps Digital Output 3
Programming Terminal units: None
Minimum Value: 0 (#1), 16 (#2)
Maximum Value: 15 (#1), 31 (#2)
Default Value: 7
Description: This parameter determines which bit of one of the two
Digital Output fast parameters will control Digital Output 3. Entering a
bit value of 0 – 15 will cause the Digital Output 1 (par 450) to control
digital out 1. Entering a bit value of 16 – 31 will cause the Digital
Output 2 (par 454) to control digital out 1. When the bit value is 1, this
output will be high.