Chapter 6

StartĆUp

6-13

Figure 6.8

Digital Reference Input - Lead/Follower Example

+4096

0

-4096

Encoder

Encoder PPR

P563 = 1024

One/Two/Quad

P 567 = 4

DIGITAL

SCALE

P564 = 875

DIGITAL

Filter

P566 = 0

OFFSET

P565 = 0

DRIVE 2

+4096

0

-4096

0

1

P569

Digital

Multiplier

Select

DIGITAL

MULTIPLIER

CONSTANT

P568 = 1000

DIGITAL

MULTIPLIER

FAST PARAM

P453

1395 Drive

Velocity Ref

Whole (P154)

Dig Ref Whole

Dig Ref Fraction

+4096

0

-4096

Encoder

Encoder PPR

P563 = 1024

One/Two/Quad

P 567 = 4

DIGITAL

SCALE

P564 = 875

DIGITAL

Filter

P566 = 0

OFFSET

P565 = 0

DRIVE 3

+4096

0

-4096

0

1

P569

Digital

Multiplier

Select

DIGITAL

MULTIPLIER

CONSTANT

P568 = 1000

DIGITAL

MULTIPLIER

FAST PARAM

P453

1395 Drive

Velocity Ref

Whole (P154)

Dig Ref Whole

Dig Ref Fraction

+4096

0

-4096

Encoder

Encoder PPR

P563 = 1024

One/Two/Quad

P 567 = 4

DIGITAL

SCALE

P564 = 1250

DIGITAL

Filter

P566 = 0

OFFSET

P565 = 0

DRIVE 4

+4096

0

-4096

0

1

P569

Digital

Multiplier

Select

DIGITAL

MULTIPLIER

CONSTANT

P568 = 1000

DIGITAL

MULTIPLIER

FAST PARAM

P453

1395 Drive

Velocity Ref

Whole (P154)

Dig Ref Whole

Dig Ref Fraction

In this example, the offset

(P565) is zero. To set it

for 10% (P565 = 40.96) the

digital scale must be

adjusted to maintain the

same follower ratio.

Parameter 564 for Drive 2 will

be 875 : 0.9 = 972 RPM.