Rockwell Automation 1395 Digital Reference Adapter Board User Manual

Page 67

Advertising
background image

Chapter 7

Troubleshooting

7-7

Table 6.D

Parameters

PARM

1
2
3
4
10
11
12
13
14
50
51
52
53
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122

UNITS

RPM
RPM
RPM
VLT
RPM

RPM

%
AMP
AMP

%
VLT
AMP
AMP

VLT
%
RPM

NAME

Trend 1 Output
Trend 2 Output
Trend 3 Output
Trend 4 Output
SP Output 1
SP Output 2
SP Output 3
SP Output 4
SP Output 5
Trend 1 Input
Trend 2 Input
Trend 3 Input
Trend 4 Input
Logic Status
Drive Fault
Pre Ramp Vel Ref
Ramp Vel Ref
Final Vel Ref
Arm Voltage Fdbk
Velocity Fdbk
Position Fdbk
Vel Feed Fwd
Position Error
Torque Command
Arm Current Ref
Arm Current Fdbk
Arm Cur PI Out
Arm Cur Fire Ang
Flux Command
AC Line Voltage
Fld Current Ref
Fld Current Fdbk
Proc Trim Output
CEMF Feedback
Flux Trim
Encoder Velocity

MIN

MAX

FUNCTION/CLASSIFICATION/PORT

Fast Source
Fast Source
Fast Source
Fast Source
Fast Source from Param 840
Fast Source from Param 841
Fast Source from Param 842
Fast Source from Param 843
Fast Source from Param 844
Fast Sink
Fast Sink
Fast Sink
Fast Sink
Logic Control
Fault Detection
Ramp Control
Ramp Control
Velocity Ref Control
Feedback Control
Velocity Fdbk Control
Velocity Fdbk Control
Velocity PI Control
Velocity PI Control
Torque Select
Current Ref Control
Feedback Control
Current PI Control
Current PI Control
Field Flux Control
Feedback Control
Field Flux Control
Feedback Control
Process Trim Control
Software Test Point
Software Test Point
Software Test Point

HEX

1H
2H
3H
4H
AH
BH
CH
DH
EH
032H
033H
034H
035H
64H
65H
66H
67H
68H
69H
6AH
6BH
6CH
6DH
6EH
6FH
70H
71H
72H
73H
74H
75H
76H
77H
78H
79H
80H

INIT

EE

Advertising