Ee memory request, Plc block transfer instruction data, Message operation – Rockwell Automation 1336T PLC Comm. Adapter, Series B, FRN 2.xx-3.xx User Manual

Page 173: Save/recall/initialize

Advertising
background image

7–27

Publication 1336 FORCE–5.13 –– September, 1998

This message is sent by the PLC Communications Adapter Board to
activate the BRAM functions detailed in the message request.

PLC Block Transfer Instruction Data

BTW instruction length:

4 words

BTR instruction length:

3 words

Message Length

4

Header

Word 1

Header

Word 1

PLC Decimal Value

-31998

Note Used

PLC Decimal Value

770 –– Message OK

0

-31998 –– Message Error

0

EE Command

EE Save
EE Recall
EE Default Initialize

EE Command

Value

00
01
02
03

Message Structure

Header

Word 2

Header

Word 3

Header

Word 4

Header

Word 2

Header

Word 3

0

PLC Request –– Block Transfer Write

Drive Response –– Block Transfer Read

Message Operation

The BRAM memory function allows three different message
requests:

BRAM Save saves parameter and link information from working
memory or RAM to BRAM.

EE Recall retrieves the last saved data from BRAM and places it
in working memory or RAM.

EE Default Initialize sets all parameter values and links to default
in RAM without altering contents in BRAM.

If an error has occurred, word 2 of the response returns a value of
-31998.

EE Memory Request

Save/Recall/Initialize

Advertising